Hi,

 

I would like to know what is the best practices and your expirience on setting and how to configure (NVMe) flash cache card to work on a fabric pool aggregate.

 

Some facts about the platform:

Ontap 9.1p13

FAS9000 with NVMe card (caching currently disabled)

two sata aggregates both of them are fabric pools

the application hosted on those aggregates is mail application with 95% read and 5% write workload

 

One KB articel about enabling flash cache on a fabric pool aggregate states this command:

 

clusthershell> node run <node_name>
nodeshell> options flexscale.flash_pool_caching on

 

another sources says enable it like this:

 

system node external-cache modify -is-hya-enabled true

 

Does it matter which command to use? Are they doing both the same = enable flash cache on flash pool aggregates?

 

And there are a couple other caching options like mbuf-inserts, pcs-size, rewarm

Which setting for a flash cache/flash pool combination works best?

 

The current configuration looks like this:

 

netapp::*> system node external-cache show -node netapp-*

Node        enabled    rewarm    mbuf-inserts    pcs-size    hya-caching

----------    -------    ------    ------------    --------    -----------

netapp-01    true      true      true            4096        false

netapp-02    true      true      true            4096        false

netapp-03    true      false     true            894         false

netapp-04    true      false     true            894         false

netapp-05    true      false     true            894         false

netapp-06    true      false     true            894         false

netapp-07    true      false     true            894         false

netapp-08    true      false     true            894         false

netapp-09    true      false     true            894         false

netapp-10    true      false     true            894         false

netapp-11    true      false     true            894         false

netapp-12    true      false     true            894         false

12 entries were displayed.

 

Highly appriciate any input, so far I only got feedback "it depends" and unfortunately that option is not available ;-)

 

Thanks

Alex

 