Hello All,
Trying to help a customer out convert a pair of controllers that were in a metro cluster into a HA pair, FAS3270 with IOXM.
We are using new disks so wiped out all disk ownership and installed the new disks, completed a option 4 and installed ONTAP on both, then 1 of the 2 nodes died and would not boot so replaced it with a new node, completed the node replacement process and got the node back up, enabled CF from the first time and it wouldnt syncronise, did a CF monitor and both links showed as down, this is where it gets odd.
Currently running 1 cable between c0a, looking for a 2nd cable now, we do see a green light.
1st node -
dersan03*> ic status
Link 0: down
Link 1: down
IC RDMA connection : down
dersan03*> ic config show
Interconnect Type: iWARP
Local System ID: 1575077239
Partner System ID: 1574064502
c0a: flags=0x1f4e867<UP,BROADCAST,RUNNING,MULTICAST,TCPCKSUM> mtu 9000 PRIVATE
inet 192.168.1.174 netmask 0xffffff00 broadcast 192.168.1.255
ether 00:a0:98:1d:83:c4 (auto-10g_twinax-fd-up) flowcontrol full
c0b: flags=0x174e867<UP,BROADCAST,RUNNING,MULTICAST,TCPCKSUM> mtu 9000 PRIVATE
inet 192.168.2.246 netmask 0xffffff00 broadcast 192.168.2.255
ether 00:a0:98:1d:83:c5 (auto-unknown-enabling) flowcontrol full
Node2 -
dersan04*> ic status
Link 0: down
Link 1: down
cfo_rv connection state : NOT CONNECTED
cfo_rv nic used : 0
cfo_rv connection role : source_rv
cfo_rv1 connection state : NOT CONNECTED
cfo_rv1 nic used : 1
cfo_rv1 connection role : none
cfo_rv2 connection state : NOT CONNECTED
cfo_rv2 nic used : 1
cfo_rv2 connection role : not applicable
dersan04*> ic config show
Error: Command not supported on this platform.
I get the feeling there is a misconfig on node02 but ha-config for both chassis and controller is set to ha, psm-cc-config is unset and the partner system ID's are correct.
What am I missing, crying in pain over here, both nodes running 8.2.4P6, confirmed part numbers between the 2 controllers are the same but the revision number is different.
Thanks in advance.
John