Quantcast
Channel: ONTAP Discussions topics
Viewing all articles
Browse latest Browse all 4988

About the alert of DualControllerHa_Policy

$
0
0

There were one of the NetApp was upgraded to ONTAP 9.8, after upgraded there were random trigger this alert, if I disable this policy thought command “system health policy definition modify -monitor system-connect -policy-id DualControllerHa_Policy -node <node> -enable false”, is that will disable the alert when trigger the real alert? EMS log as below:

---------------------------------------------------------------------

</LR>

<LR d="28Sep2021 10:33:23" n="dc7fas8202_node1" t="1632796403" id="0/79164837199883" p="1" s="Ok" o="schmd" vf="" type="1" seq="483530" >

<hm_alert_raised_1

        detailed_info="Alert Id = DualControllerHa_Alert , Alerting Resource = 50:0a:09:80:0b:0c:8c:2b"

        monitor="system-connect"

        alert_id="DualControllerHa_Alert"

        alerting_resource="50:0a:09:80:0b:0c:8c:2b"

        probable_cause_description="Configuration_error"

        alert_corrective_action="1. Halt all controllers that are connected to shelf 1.0.&#x0A;2. Connect shelf 1.0 to both HA controllers following the guide applicable to your shelf.&#x0A;3. Reboot the halted controllers."

        possible_effect="Access to shelf 1.0 will be lost with a single controller failure."

        additional_info="&quot;Shelf UUID: 50:0a:09:80:0b:0c:8c:2b&quot;&#x0A;&quot;Shelf ID: 0&quot;&#x0A;&quot;Status: ok&quot;&#x0A;&quot;Total Number of Paths: 2&quot;&#x0A;&quot;Connected Nodes: dc7fas8202_node0&quot;&#x0A;&quot;Number of Connected Nodes: 1&quot;&#x0A;&quot;Module Type: IOM12&quot;&#x0A;&quot;Shelf: 1.0&quot;&#x0A;"

        tags="quality_of_service"

        acknowledge="0"

        acknowledger=""

        suppress="0"

        suppressor=""

        asup_enable="0"/>

</LR>

<LR d="28Sep2021 10:36:33" n="dc7fas8202_node1" t="1632796593" id="0/10647223926835" p="1" s="Ok" o="mgwd" vf="" type="1" seq="483531" >

<callhome_hm_alert_major_1

        subject="Health Monitor process schm: DualControllerHa_Alert[50:0a:09:80:0b:0c:8c:2b]"/>

</LR>

-----------------------------------

The things we want to know is if we disable DualControllerHa_Alert, when there was some problem about connection from controller to shelf, the alert will still can be trigger out or not?