Quantcast
Channel: ONTAP Discussions topics
Browsing all 4865 articles
Browse latest View live

7MTT Cifs Migration Keeping IP and Identity

We are trying to migrate several cifs filers & vfilers to cmode and in our testing have come across some problems when trying to follow the transition guide.Though not mentioned, you can't create a...

View Article


FAS8020 supporting IBM LTO8 HH drives since the ONTAP upgrade

Looking for help and advice for the following issue since the ONTAP upgradeFAS8020 supporting IBM LTO8 HH drives since the ONTAP upgrade please? Does  ONTAP v9 onwards, support IBMLTO8 HH Drives. I...

View Article


Commit a file to WORM via api

Hello,in our clusters we actually do commit to WORM state changing attributes via NFS. I think this is the preferred way and the guide "Ontap 9 archive and compliance using snaplock technology power...

View Article

ONTAP 9.5

What are the new features in ontap 9.5 and changes made in regards to syncronous mirroring?

View Article

NFS/CIFS Encryption

In terms of end to end encryption over NFS/CIFS, I know there can have NetApp Volume Encryption which will happen on volumes. What about encryptions from VM clients and to the NetApp storage? In NFS...

View Article


how to switch ifgrp ports from 1Gb to 10Gb in 9.1 ?

HiIs there a recommended procedure to switch the ifgrp ports from 1Gb to 10Gb in ONTAP 9.1 ?In the olden days of 7-mode it was a relatively simple procedure edit rc files and failover the nodes etc.Not...

View Article

using conditional execution in CLI

Is there a way to use conditional logic on the OnTap CLI between different fields? Like if I wanted to get all users that are over 1TB OR using more than 1million files? E.g. something likequota report...

View Article

Volume move failing with 'undergoing transition' error (EDIT: never mind, all...

UPDATE: After some more investigation, I discovered that the volume was no longer needed, so I could just delete it. No need to resolve this problem anymore. --- Mixed 4-node FAS8060/8200 cluster...

View Article


Restoring a LUN from with a Volume for 8.2.5 7-Mode

Greetings,Have only been here a couple of months and have run into an area that I am not sure about proceeding with.  Any assistance is greatly appreciated.I have four ESXI luns, that are within a...

View Article


AutoSupport options...

Hi All When using cluster mode. Is it possible to have AutoSupports sent to an internal Web server location as opposed to using a SMTP server..? My AutoSupports cannot be sent direct to netapp as there...

View Article

7MTT Snapmirror replication and network compression

Can't figure out how to get compression enabled on a snapmirror relationship established with 7MTT. Relationship is created fine using the tool. Non-compressed transfer works just fine. I've got many...

View Article

Fabric Metrocluster ATTO connectivity with NetApp FAS8200

Below please find the log. From ATTO, I typed "sastargets" and I can see all netapp disk and disk shelf. On the MDS, I found wwpn of ATTO and NetApp controller fc port on flogi database. Any idea what...

View Article

Aggregate relocation or storage failover impact to hosts with MPIO

Hey there.Under SAN configurations for HA pair, attempting to reduce the "loss of reduntancy" aspect while ontap software upgrades... Was wondering if the below scenario make sense.MPIO on hosts will...

View Article


Total size of snapshots for all volumes in aggregates

I need to know how much space being taken by all snapshots for all volumes in one or each one of aggregates.  What commands or scripts can do that? Thanks in advance for your help.

View Article

Install NetApp Host Utiliies for Windows 7.1 on Windows Server 2019

Hello!According to the Interoperability Matrix Tool, NetApp Host Utiliies for Windows 7.1 is supported by Windows Server 2019 and Windows Server 2016.I tried to install NetApp Host Utiliies 7.1 on...

View Article


DFM upgrade failed ( Unable to upgrade the database to the latest file format )

Hi, I have been trying to upgrade the DFM version from 4.0.2 to 5.2.3  ( Oncommand core package for 7 mode) . The new version software is sucessfully installed. But while trying to restore the backup...

View Article

ONTAP 9.4 2750 controllers :: New Switched cluster setup failing.

Hi, I have 3 nodes 2750 each with 2 controller. I have 2 netapp switch.e0a from each controller is connected to Switch A 6 connections and e0b from each controller to Switch B. All connections are...

View Article


SnapMirror TDP too slow

Hi gurus,I'm transferring a 6TB encrypted 7-mode volume to a C-Dot storage on AWS and transfer speed is about 2.4MB per minute.Can the encryption impact this transfer? Is there any flag or option to...

View Article

ONTAP 9.4 2750 controllers :: New Switched cluster setup failing.

Hi, I have 3 nodes 2750 each with 2 controller. I have 2 netapp switch.e0a from each controller is connected to Switch A 6 connections and e0b from each controller to Switch B. All connections are...

View Article

how to change the espsilon node using powershell cmdlets

Hi All, I'm trying to automate the ontap upgrade process and i need to trasnfer the epsilon node to another node. I know we can use Invoke-NcSsh and then use the normal ontap command but i want to...

View Article
Browsing all 4865 articles
Browse latest View live