Quantcast
Channel: ONTAP Discussions topics
Browsing all 4878 articles
Browse latest View live

SVM with CIFS/NFS - Cache of Windows/ NIS GID

Hello, I have a SVM running CIFS/NFS with Unix security on the share. I have set up AD Auth as it should. I can create a file from Windows mapping the CIFS share. I can create a file from my Linux box...

View Article


migrating vfiler to another storage system - without retaining ipspace config

so a peculiar problem. We need to move vfilerA to another storage system. Under normal circumstances, this is easily achieved by vfiler-DR. However in this case, there is a differnet network setup on...

View Article


Globally increase SnapVault retries?

Hi,We have a large number of SnapVault jobs that run each night and of those it seems a small number fail (never usually the same ones each time) with network errors. Manually retrying them in the...

View Article

Image may be NSFW.
Clik here to view.

***Controller global status monitor*** Can this monitor in scom overrided to...

Hello Everyone, Can somebody help with following monitor In Microsoft SCOM Alert Name : Controller global status monitorMonitor Name : Data ONTAP: Controller Global Status Monitor One of my customer...

View Article

Snapvault : idle size of Aggregate

 What is idle size of Aggregate

View Article


netapp configuration tools

hi all ,  is there any tools from netapp to do solution configuration including the controller , disk, part and cabling . i have used the Synergy  but it is not showing the cablling between i am just...

View Article

is there any command to find NetApp FAS model name via putty in 7 mode.

Hi all,         I am new to NetApp storage. Could anyone help me the command to find NetApp model name (FAS XXXX). Other than sysconfig -a command. ThanksLakshmanan

View Article

SMB3 encrypt traffic

Looking for some information on SMB3. If I use it to encrypt data in motion is it an all or nothing? Can it be setup so clients that support SMB3 will access it encrypted and clients that only support...

View Article


dwdm stretched 7-mode metrocluster

Hi all, I have inherited a stretched 7-mode metrocluster: using Brocade FC switches, 2 fabics, 2 ISLs. I need to change the DWDM provider so just wondered if anyone has any advice / gotchas when...

View Article


VSCAN on 7-mode for vfilers

Hi all, below is how we have set up our vscan per vfiler: robvfiler@filer1> vscanVirus scanning is enabled.This vfiler is configured to use vscan servers connected to the host filer.Secondary...

View Article

statistics lun show latency

Hi All, When test latency with command "statistics lun show" in Cmode 8.3, the latency display very high and over ten thousand or over ten thousand ms. But when use command "statistics show -object lun...

View Article

SVM: Change IP Address to another subnet/ipspace

Hi everyone,   I need to change the svm ip address to another subnet (vlan).  I've already created the interface vlan/subnet/ipspace/broadcast domain.  I'm trying to change the svm lif association to...

View Article

Missing Configuration Files FAS2050

Good afternoon, All. I work for a subsidiary of a large corp, and I inherited a FAS2050 running 7.3.7P3 7 Mode.  Out of the box, I did a wipe and selected 4a to create a Flexvol.  Everything went fine...

View Article


access to /etc/quotas on vFiler

Hi I have root account on netapp 7-mode ontap and can access vFiler  using vFiler context filer_name command to see listed quotas.I need to modify those quotas for the filer and here i have a problem,...

View Article

What could be a cause that system make upgrade from 32 bit to 64 bit in...

HelloI do have a questionWhat is the possibility way that this things happened? How could that happened? Tue May 17 12:50:24 CEST [matrix2:wafl.64bit.upgrade.vol.nospc:notice]: The 64-bit upgrade...

View Article


7MTT with Snapmirror Relationships

We have 2 old 7-Mode systems (Main and DR site) Use 7MTT 2.3.17-Mode systems is 8.2.3CMODE 8.3.2P1  We have CMODE system only on DR site now, CMODE system on Main site will be shipped later (next...

View Article

cDOT - convert 2 node cluster to 2 node stretched Metrocluster

Hello, We have a lab setup that consist of a 2 node cDOT cluster running 8.3 soon to be ONTAP9. We would like to see if we can convert this 2 node HA pair into a stretched MetroCluster. Yes, both nodes...

View Article


Image may be NSFW.
Clik here to view.

alienvault ossim alerts on netapp storage

hi!we are currently using alienvault ossim as our siem soultion.and for some reason we continuously getting "Malware infection" on the netapp ip.AlienVault NIDS: "ET TROJAN Linux/dtool IRC Command...

View Article

Netapp.manage.NaAPIFailedException: Unable to find API:

Hi ,     I have wriiten a cpde to fetch volume information from Oncommand Unified manager 6.3 .I am using OnCommand DFm command (dfm-schedule-create) to fetch the information but iam getting an...

View Article

SVM based latency/iops how meaningful are they ?

Within System Manager, or OnCommand Performance Manager, you can find SVM based performance widget, show us for instance latency and IOPS.Because of this, some people here believe we should create...

View Article
Browsing all 4878 articles
Browse latest View live


<script src="https://jsc.adskeeper.com/r/s/rssing.com.1596347.js" async> </script>