Hi All,

 

I am unable to config specific smtp mail settings. Get error message as Warning: Unable to validate mailserver "smtp.migits.net:2555". Reason: Weird server reply.

 

Kindly advice on the below commands


RUH-PS-DM5000H::> event config modify -mail-server smtp.migits.net:2555 -mail-from ruh.DM5000@alerts.migits.net

Warning: Unable to validate mailserver "smtp.migits.net:2555". Reason: Weird server reply.
Do you want to continue? {y|n}: n

RUH-PS-DM5000H::> event config modify -mail-server smtp.migits.net:2555 -mail-from ruh.DM5000@alerts.migits.net

RUH-PS-DM5000H::> event notification destination create -name storage-admins -email it.systems@migit.net

RUH-PS-DM5000H::> event notification create -filter-name important-events -destinations storage-admins

 

RUH-PS-DM5000H::> event config shownotification destination show
Name                            Type                                                            Destination
--------------                 ----------                                                         ---------------------
snmp-traphost        snmp                                              - (from "system snmp traphost")
storage-admins email it.systems@migit.net (via "smtp.migits.net:2555" from "ruh.DM5000@alerts.migits.net", configured in "event config")
2 entries were displayed.

 


SMTP Mail Warning: Unable to validate mailserver "smtp.******.net:2555". Reason: Weird server reply.

$
0
0

Hi All,


I am unable to config specific smtp mail settings. Get error message as Warning: Unable to validate mailserver "smtp.******.net:2555". Reason: Weird server reply.


Kindly advice on the below commands


RUH-PS-DM5000H::> event config modify -mail-server smtp.******.net:2555 -mail-from ruh.DM5000@alerts.******.net

Warning: Unable to validate mailserver "smtp.******.net:2555". Reason: Weird server reply.
Do you want to continue? {y|n}: n

RUH-PS-DM5000H::> event config modify -mail-server smtp.******.net:2555 -mail-from ruh.DM5000@alerts.******.net

RUH-PS-DM5000H::> event notification destination create -name storage-admins -email it.systems@*****.net

RUH-PS-DM5000H::> event notification create -filter-name important-events -destinations storage-admins


RUH-PS-DM5000H::> event config shownotification destination show
Name Type Destination
-------------- ---------- ---------------------
snmp-traphost snmp - (from "system snmp traphost")
storage-admins email it.systems@*****.net (via "smtp.******.net:2555" from "ruh.DM5000@alerts.******.net", configured in "event config")
2 entries were displayed.

 

DM5000H Storage with Ontap 9.7 with information alert led amber

$
0
0

Hi Team,

 

We have new storage configured and all looks good but we have an information alert led  amber.

This appeared once we had down a power cyle of the system and reseated one of the power supply and the controller.

 

No fault as per logs and ,Kindly advice

 

regards

ahmar

How can we access GUI (Stretched MetroCluster) running on 7mode 8.2 of your 2Node FMC

$
0
0

We have 2node FMC (stretched MetroCluster) running on Data Ontap 8.2 [7-Mode] and we are looking for GUI access option. Is that available?

performance counter & rest api

$
0
0
Hi Experts.
I have some mathmetical problem using statistic to monitor performance.
The below is result of statistics API (# /api/cluster  with ontap 9.6)
Large digits of number has shown and I would like to change this into milli second measurement.
For the information, statistics API poll data every 3 seconds, which is near real-time.
Any idea or comments on this?
 
and then what is latency unit of metric.*
what are the 392units below (ms or us)

"latency": {

      "other": 2060,

      "total": 392,

      "read": 469,

      "write": 237

 
 
 
Please provide a detailed description of metrics.* and stastics.* 
 
####output of /api/cluster###########

"metric": {

    "timestamp": "2020-07-14T07:30:30Z",

    "duration": "PT15S",

    "status": "ok",

    "latency": {

      "other": 2060,

      "total": 392,

      "read": 469,

      "write": 237

    },

    "iops": {

      "read": 23822,

      "write": 22332,

      "other": 970,

      "total": 47125

    },

    "throughput": {

      "read": 2648275729,

      "write": 365964117,

      "other": 584936,

      "total": 3014824783

    }

  },


"statistics": {
    "timestamp": "2020-07-14T07:31:00Z",
    "status": "ok",
    "latency_raw": {
      "other": 8052914094221,
      "total": 79593320562765,
      "read": 50965207630433,
      "write": 20575198838111
    },
}

snapmirror update monitor

$
0
0

Hi,

 

We know Unified Manager could send email notice if SnapMirorr update problem, could any method let Unified Manager also send email notice if SnapMirror update success? Could ems subscribe to Unified Manager include SnapMirror update success? If yes, which ems event subscribe?

 

Best regards,

 

Chunjg

Statistics Object offbox_vscan not found on Netapp Simulator

$
0
0

Statistics Object offbox_vscan not found on Netapp Simulator

Ref Link: https://library.netapp.com/ecmdocs/ECMP1366831/html/GUID-0F885801-D5AE-4FCF-93D0-1894590FB2D4.html

 

 

 

cluster161::> set -privilege advanced Warning: These advanced commands are potentially dangerous; use them only when directed to do so by NetApp personnel. Do you want to continue? {y|n}: y cluster161::*> statistics catalog counter show -object offbox_vscan Error: show failed: Object "offbox_vscan" was not found. cluster161::*>

 

 

 

Need this command to collect Vscan statistics. 

LUN Dedupe and space usage

$
0
0

Working with a small FAS2750, 2 x ~10tb Aggregates.   The only intention for this system is to use for VMware datastores via iscsi.

 

It seems thin volumes, and unreserved space luns are the general recommendation for this setup.  What isn't clear to me is how to take advantage of the space savings from dedupe.  As far as I can tell the only way to access this saved space would be to over provision luns from a volume which just feels kind of strange.  I'd basically be taking a guess at what savings I might get and would need to watch space fairly closely.

 

Looking for suggestions or just confirmation that basically over provisioning luns is the only way to use the space savings in this scenario.


Volume Disaster Recovery

$
0
0

I am trying to do  a DR test for one volume in Netapp CDOT cluster. 

Can anyone help  me out with the steps 

Change/Edit Timezone for ONTAP

$
0
0

Running v9.6P3.  I'm trying to correctly set the timezone for our NetApp.  I goto Settings\Data and Time and I've tried adding a known internal time server and have also tried a valid external.  After saving and then waiting for 30+ minutes, the time doesn't change and still shows "Etc/UTC" and records time 5 hours ahead of my actual timezone (CST).  This is extremely annoying in logs and viewing snapshots.  How can I correctly set this for my timezone?  Thanks!

Netapp 9.7 -Security key-manager setup" command Error: 13001

$
0
0

 

Hi Team,

Kindly advice on the below error appearing while trying to enable encryption feature.

 

For DM5000H storage, while enabling encryption option on volumes getting below error

ONTAP API Failed: Failed to start conversion on volume "RUH_PS_SAS_NPD_Vol01_vol" in Vserver "SVM_iSCSI". Reason: Key manager is not configured on the cluster. To configure it, run "security key-manager setup" command. (Error: 13001)

 

Thanks

Ahmar

Metrocluster

$
0
0

In two-node (FMC) configuration (7mode MetroCluster) ontap 8.2.
When one node went offline another taken over the services but I don't see metrocluster switchover has happened and seems as simple HA pair when one goes down another will be in Node1takenover> to serve data to the client. Have you seen a similar setup if yes, please share your experience.

AV scan and Latency

$
0
0

Hi,

 

we have AVscan setup , but not used it, 

 

1)   user experience slowness accessing the files during scanning process.

2) if there are encrypted files or password files how the scan works?

 

thanks

The cluster replication heartbeat to peer cluster failed

$
0
0

Hi Everyone,

 

In my storage system I'm getting the below alert that heartbeat to peer is failed for some time period. Kindly suggest how to check and troubleshoot the below alert. Current version is 9.7P5

 

alertTrap: A user-defined trap indicating a condition that should be corrected immediately, such as a failed disk.cluster.repl.peerNW.unreachable:The cluster replication heartbeat to peer cluster 786cb0c6-aa62-11ea-9d0c-000d3a2cf2d3 failed for at least 30

3-Site Replication

$
0
0

Hi Team,

Do we have support for 3-site replication in latest CDOT 9.7P5?

One of the customer has Primary Site, Near DR and FAR DR. Would like to check if NetApp supports 3-site replication?


Consequences of turning snapvault / snapmirror off

$
0
0

hello all,

on a 7mode filer with version [NetApp Release 8.2.4P5] we are trying to move a volume from one aggregate to another but it gives the below error:

 

FilerA> vol move start VolNAme  aggr1
vol move: Specified source volume has a qtree snapmirror destination

 

if we turn the snapvault / snapmirror off, move the volume then turn it back on there will be any risk or configuration loss on our snapvault / snapmirror ? if yes then what is the perfect solution for the matter ?

 

much thanks in advance...

Unable to pair OnCommand API Services 2.2 with Active IQ Unified Manager 9.7

$
0
0

Interoperability matrix tool doesn't list the compatibility against Active IQ 9.7 and API Services 2.2

I tried pairing API Services and Active IQ with throwing error as depicted in attached screen print.Error.JPG

Installation guide of API Services 2.2 doesn't talk about any compatibility issue with Active IQ 9.7

Any help on this pairing would be really appreciated.

 

Thanks.

Node Morgan2" has taken over Morgan 1

$
0
0

Hi guys, when i logged on the ontap system manager this morning, this is the message that was on my overview "Node "Morgan02" has taken over node "Morgan01". ssh into the management and check 

first command 

Morgan::> system health subsystem show
Subsystem Health
----------------- ------------------
SAS-connect ok
Environment ok
Memory ok
Service-Processor ok
Switch-Health ok
CIFS-NDO ok
Motherboard ok
IO ok
MetroCluster ok
MetroCluster_Node ok
FHM-Switch ok
FHM-Bridge ok
SAS-connect_Cluster
ok
13 entries were displayed.

 

Second, i tried  cluster peer health show:

This table is currently empty.

Warning: Unable to list entries on node Morgan-01. RPC: Couldn't make
connection [from mgwd on node "Morgan-02" (VSID: -1) to mgwd at
169.254.26.183]

 

Any help will be greatly appreciated to troubleshoot this issue 

Volume Performance and latency maximum and minimum values

$
0
0

Hi All,

 

Could you please guide me with what are the Performance and latency maximum and minimum values for the volume and cluster ?

System Manager Updates for C-Mode

$
0
0

Hi guys. Running C-Mode 9.3 clusters. I see system manager is baked into the cluster. Does this mean that any updates to system manager ship with the underlying OnTap version and hence to update system manager one updates the OnTap version?